Enquire
Water Cooling Tower System 2

Water Cooling Tower System

1. Streamlined inlet duct with small resistance and large volume.
2. Closed circulation, no impurity entering, pure water medium, no scaling.
3. Robot welding heat exchanger coil, weld high-pressure resistance, good antifreeze effect.
4. Start and stop the sprinkler system according to ambient temperature.
5. The water cooling tower system adopts a modular and compact design, easy to move.

Share to:

Product details

Introduction of Water Cooling Tower System

  The water cooling tower system uses a two-stage cooling mode, that is, the first stage cooling adopts air cooling, which depends on the wind to cool the cooling coil. Secondary cooling adopts air cooling and spraying, and secondary cooling is used when the ambient temperature is relatively high. At the same time as air cooling, the spraying system will spray water on the surface of the cooler, which will take away the heat of the coil when the water evaporates. The hot and humid air will be recovered by the dehydrator through the fan on the top and out of the machine, to achieve the cooling effect. When the ambient temperature is relatively low, primary cooling is used. The consumption of spray water is only 0.1-0.2‰ per unit flow rate. The upper part is equipped with a water-spraying device and the bottom is a water tray. During operation, the circulating liquid enters into the tube from the top of the coiled tube through the coil wall and is exchanged with the outside of the coil with the spray water and air. The strong wind force of the fan makes the spray water fully cover the outer surface of the coil, thus improving the heat exchange efficiency. After spraying the heat of the water and air suction cup wall, the temperature rises, part of the water changes from liquid to a gaseous state, and a large amount of capacity is taken away from the pipe wall. The water in the hot and humid air is mainly printed into the heat exchange layer of the seasoning layer by the water plate boundary, and the hot air is discharged. The heat exchange layer spray water is cooled by the fresh air flowing through it, and the temperature is lowered. It flows into the sink and is then fed by the pump into the spray system for further circulation. The water lost to the air is automatically adjusted by a water level control device.

Induction cooling tower & industrial water cooling system

Features of Water Cooling Tower System

● Low-temperature automatic shut down sprinkler pump or fan system with special water collector, to achieve electricity and water-saving, energy-saving operation mode.

● The s-row coil is designed in such a way that the resistance is reduced and the risk of freezing damage of the coil is reduced, which is conducive to the anti-freezing of drainage in winter.

● The selection of high-performance aluminum and zinc plating corrosion plate, coil after acid washing passivation, the use of automatic welding machine welding, welding seam no leakage, high-pressure resistance, so that the machine’s life to more than 15 years.

● Closed circulation, no impurities, circulating medium for pure water, will not produce a scaling phenomenon. Maintenance costs are low.

● Automatic digital temperature control, support the dry operation mode without spray in winter, can also choose manual/automatic start fan or spray system according to the water outlet temperature, realize water and electricity saving, reduce the operation cost.

● High-quality bearings are used for both fan and water pump, airfoil hollow aluminum alloy axial flow fan, tilting structure design, streamlined inlet air duct, small wind resistance, large air volume, good performance, with Siemens, ABB, and other well-known motors, to ensure long-term stable operation of the pump.

Water cooling tower

Parameters of Water Cooling Tower System

Model

Flow rate

Fan parameters

Spray pump

Pipe diameter

    

Power

Blowing rate

Power

Flow rate

In and out of the water pipe

Replenishment
/overflow

Drain contamination

  
 

M³/h

kw

M³/h

kw

M³/h

DNmm

DNmm

DNmm

SL-30

30

1.5*2

19200*2

1.5

45

80

25

32

SL-40

40

1.5*2

25600*2

1.5

45

100

25

32

SL-50

50

2.2*2

32000*2

1.5

45

100

25

32

SL-65

65

2.2*2

41600*2

1.5

45

100

32

40

SL-80

80

3.0*2

51200*2

2.2

114

120

32

40

SL-100

100

4.0*2

64000*2

2.2

114

125

32

40

SL-125

125

5.5*2

80000*2

3.7

140

150

32

50

SL-150

150

7.5*2

96000*2

3.7

140

150

32

50

SL-175

175

7.5*2

112000*2

5.5

192

150

32

65

SL-200

200

11*2

128000*2

5.5

192

200

32

65

Applications of Water Cooling Tower System

  As the main auxiliary equipment of the heat treatment industry, the water cooling tower system is used in heat treatment quenching medium, controllable atmosphere multi-purpose furnace, induction heating furnace, vacuum furnace, etc. Central air conditioning, forging, casting, chemical industry, food, injection molding, printing, generator set, power plant, glass melting kiln, and other fields.

induction heating machine tool with Water Cooling Tower System

Send Inquiry

error: